The product complies with the following standards: GB/T17467-1998 “High-voltage and low-voltage pre-installed substation”, DL/T537-93 “6-35kV box-type substation ordering technical conditions”.The oil tank adopts fully sealed structure and is equipped with oil temperature gauge, oil level gauge, pressure gauge, pressure release valve, oil drain valve and other components to monitor the operating condition of the transformer.
Translated with www.DeepL.com/Translator (free version)
Product Highlights
The whole product has small volume, easy installation and maintenance, low noise, low loss, anti-theft, strong overload capacity, full protection and so on.
It is suitable for new neighborhoods, green belts, parks, stations and hotels, construction sites, airports and other places.
The product complies with the following standards: GB/T17467-1998 “High-voltage and low-voltage pre-assembled substation”, DL/T537-93 “6-35kV box-type substation ordering technical conditions”.
YB27-12 series American pre-installed box-type substation, the whole product has a small size, easy installation and maintenance, low noise, low loss, anti-theft, strong overload capacity, full protection and other characteristics.
The substation is suitable for new neighborhoods, green belts, parks, stations, hotels, construction sites, airports and other places. It is suitable for 10kV ring network power supply, dual power supply or terminal power supply system, as a substation, metering, compensation control and protection device.
The product complies with the following standards: GB/T17467-1998 “High-voltage and low-voltage pre-installed substation”, DL/T537-93 “6-35kV box-type substation ordering technical conditions”.
The product complies with the following standards: GB/T17467-1998 “High-voltage and low-voltage pre-installed substation”, DL/T537-93 “6-35kV box-type substation ordering technical conditions”.The oil tank adopts fully sealed structure and is equipped with oil temperature gauge, oil level gauge, pressure gauge, pressure release valve, oil drain valve and other components to monitor the operating condition of the transformer.
Working Conditions
Ambient air temperature: -30℃~+50℃;
Altitude : Maximum installation altitude: 2500m;
Outdoor wind speed is not more than 35m/s;
Relative humidity: daily average value not more than 95%, the monthly average value not more than 90%;
Seismic intensity not more than 8 degrees;
No fire, explosion danger, serious pollution, chemical corrosion and severe vibration.
Applied IEC standards
Compact substations : IEC61330
MV metal enclosed Switchgear : IEC 62271-200,IEC 60298
Switch Disconnector (Isolators) ,and earthing
Switches : IEC 60694-60129-60265 Power Transformer : IEC 60076
Low voltage switchgear : IEC 60439-1
Low Voltage breakers : IEC 60947-2
Structural Characteristics
Fully insulated, fully sealed, maintenance-free, reliable guarantee of personal safety;
Compact structure, volume is only 1/3-1/5 of the same capacity of the European transformer, low height;
Can be divided into box structure, to avoid the pollution of the oil in the transformer tank;
The high-voltage side of the full range of protection with double fuses, greatly reducing costs:
Can be used for ring network as well as terminal, and the cable head can be plugged and unplugged in 200A load current in emergency;
The box body adopts honeycomb double sandwich composite board, insulating and heat dissipation function; 7, the low-voltage side is equipped with electronic phase-loss protector, when there is abnormal voltage in the system, it can quickly break the main inlet switch;
The oil-immersed load switch or SF6 load switch on the high-voltage side can be upgraded electrically, laying the foundation for realizing distribution network automation.
Adopt oil-immersed S9 or better performance S11 series transformers.
Technical Parameters
Technical parameter
No.
Item
Unit
Technical Parameters
1
Rated Voltage
kV
10/0.4 (High Voltage/Low Voltage)
2
Working Voltage
kV
12 (High Voltage Side)
3
Rated Frequency
Hz
50
4
Rated capacity
kVA
50-1600
5
1 minute frequency withstand voltage
kV
35
6
Lightning Impulse Voltage
kV
75
7
Cooling mode
Oil immersion self-cooling
8
High-voltage backup fuse breaking current
kA
50
9
Insertion fuse breaking current
kA
2.5
10
Ambient temperature
℃
-75
11
Allowable temperature rise of coil
K
65
12
No-load voltage regulation
±5% or ±2*2.5%
13
Noise level
dB
50
14
Protection class
IP43
Transformer technical parameters
We use the new S9 series transformer body, low loss, good overload capacity, short-circuit resistance, all fasteners are anti-loosening treatment, free of core lifting; can also choose to use the better performance of the S10 series and S11 series of transformers
Capacity
(kVA)
Voltage (kV)
No-load current (A)
Impedance Voltage
No-load current (A)
High Voltage
Low Voltage
S9
S10
S11
S9
S9
S11
S9
S10
S11
50
10土5%
Or
±2×2.5%
0.4
2
1.9
0.75
0.17
0.15
0.12
0.87
0.83
0.87
63
1.9
1.8
0.7
0.2
0.18
0.14
1.04
0.99
1.04
80
1.9
1.7
0.7
0.25
0.22
0.175
1.25
1.2
1.25
100
1.8
1.55
0.65
0.29
0.26
0.2
1.5
1.42
1.5
125
1.7
1.45
0.65
0.34
0.3
0.235
4
1.8
1.72
1.8
160
1.6
1.3
0.6
0.4
0.36
0.27
2.2
2.12
2.2
200
1.5
1.2
0.55
0.48
0.43
0.33
2.6
2.5
2.6
250
1.4
1.1
0.5
0.56
0.5
0.39
3.05
2.9
3.05
315
1.4
1
0.45
0.67
0.29
0.465
3.65
3.45
3.65
400
1.3
1
0.4
0.8
0.71
0.56
4.3
4.15
4.3
500
1.2
1
0.4
0.96
0.85
0.67
5.15
4.82
5.15
630
1.1
0.8
0.4
1.2
1.6
0.81
6.2
5.86
6.2
800
1
0.7
0.35
1.4
1.23
0.98
7.5
7.2
7.5
1000
1
0.6
0.3
1.7
1.5
1.15
4.5
10.3
9.8
10.3
1250
0.9
0.6
0.27
1.95
1.72
1.36
12
12.2
12
Load switch technical parameters
The load switch is oil-immersed, three-phase linkage switch, spring-operated mechanism; it can be operated with load opening and closing, and its opening and closing speed has nothing to do with the size of the operating force, and its type is available in two-position, four-position T-type, four-position V-type, and so on.
No.
Three-phase transformer capacity (kVA)
Transformer primary voltage (10kV)
XRNT Rated Curremt(A)
PRNT1 Overload protection rated current (A)
1
30
10
6
2
50
16
8
3
80
16
10
4
100
20
15
5
125
25
15
6
160
31.5
25
7
200
40
25
8
250
50
40
9
315
63
40
10
400
63
40
11
500
80
50
12
630
100
50、65
13
800
125
65
14
1250
160
100
15
1600
200
140
Dimensions and structure
Capacity
(kVA)
L
H1
H2
D
D1
160
1750
1750
1150
1170
750
200-250
1750
1750
1150
1410
750
315
1750
1750
1250
1410
750
400
1750
1750
1250
1460
750
500
1850
1750
1350
1490
750
630
1850
1750
1350
1580
750
800
1950
1750
1400
1650
750
1000
1950
1750
1450
1640
750
Substation Enclosure
Enclosure Schematic diagram
Roof
shutters
External metering unit
Lifting ring
Channel base
Door
Brick, imitation brick wall
Concrete foundation
Foundation vents
Substation Enclosure
Metal Enclosure
Metal Enclosure(Colored steel composite sheet)
Non-metal enclosure
Metal with wood enclosure
Stainless steel enclosure
Ordering Instructions
Compact Substation Inspection Process
1. Compact Substation should meet the following requirements:
Inspection certificate and accompanying technical documents, with a factory test records;
Visual inspection: Nameplate, completely accessories, insulation items without defects, cracks, part of oil-filled no leak-out, inflatable pressure high-voltage equipment indicating normal, coating integrity.
2. Construction process and description
The construction process Laying based steel → laying ground grid →compact substation handling →compact substation installation → cable termination connection.
Process Description Laying based steel (1)Indoor base of cable and based platform with 1:25 concrete mortar surface, thickness of 20mm, the surface to be smooth.
The basis of steel should be strictly in accordance with the drawings and specifications to lay and be treated with preservatives.
Equipment installation of fasteners should be used in galvanized to all products (except bolt outside).
After installing basic steel, its top should be higher than the flat ground 10mm, base-steel should have more than two place to reliable grounding.
Compact Substation between the base and the foundation to use cement mortar seal so as to avoid rain water into the compact substation ; After the cable into the Compact Substation, the gap between cable and pipe required to waterproof and seal; The bottom of compact substation need to slightly tilted to avoid water
The number of inlet and outlet and the cable diameter, can be determined according to the actual situation of the user’s location and the inlet and outlet , spacing of pipe row not less than 30mm.
Civil foundation diagramof “ground type” non-metallic Compact substation
Documents and materials
Complete set to provide the following documents
Product packing list;
Product factory test report;
Product manual instruction;
Equipment list;
Secondary wiring diagram;
The products are supplied according to the catalog and equipment list;
Ordering Instructions
Pls kindly supply following information ,if you have any enquiry on Compact substation
Altitude : ≤1000m or ≥1000m
Outdoor enclosure material: Composite plate or Metal cold rolled sheet
Can’t find an answer to your question, or want more information about our products? If so, please feel free to get in touch with our professional team. We’re here to help you drive your projects to success.