DLW Series Intelligent Universal Type Air Circuit Breaker (ACB)

DLW Series Intelligent Universal Type Air Circuit Breaker (ACB) (hereinafter referred to as Circuit Breaker) is suitable for AC 50Hz, rated voltage up to 660V (690V) and below, rated current 630A~6300A in power distribution network. The Circuit Breaker conforms to GB14048.2-2001 and IEC60947-2-1995 and other standards.

  • It is used to distribute electric energy and protect lines and power supply equipment from overload, undervoltage, short circuit, single-phase grounding and other fault hazards.
  • The Circuit Breaker has intelligent protection function and precise selective protection, which can improve the reliability of power supply and avoid unnecessary power outage. It also comes with open communication interface to meet the requirements of control center and automation system.
  • The Circuit Breaker has an impulse withstand voltage of 8000V at an altitude of 2000 meters above sea level (different altitudes are corrected according to the standard, and the maximum does not exceed 12000V above ground).

Overview

Model Definition

DLW Series Intelligent Universal Type Air Circuit Breaker (ACB)

Classification
  • According to the installation mode: fixed, drawer type
  • According to the number of poles: three-pole, four-pole
  • According to the operation mode: electric operation, manual operation (overhaul, maintenance)
Types of disconnectors

Intelligent controller, undervoltage instantaneous (or delayed) release, shunt excitation release.

Intelligent controller performance
  • Intelligent controller is divided into: H-type (for communication), M-type (general intelligent), L-type (economic);
  • It has the functions of overload long delay anti-time limit, short delay anti-time limit, fixed time limit and instantaneous. Can be set by the user to compose the required protection characteristics;
  • Single-phase grounding protection function;
  • Display function: setting current display, action current display, the main display of each line voltage (voltage display should be proposed at the time of ordering);
  • Alarm function: overload alarm;
  • Self-test function: overheating self-test, microcomputer self-diagnosis;g. Test function: test the action haracterist ics of the controller.
The normal working conditions and installation conditions
  1. Air temperature:
    Ambient air temperature is -25℃~+70℃ (LC low temperature product is -45℃~+70℃), the average value of 24h is not more than +35℃, higher than +40℃ should be used with reduced capacity. Please refer to the table of coefficient of capacity reduction.
  2. Atmospheric conditions:
    The relative humidity of the atmosphere in the surrounding air temperature of +40 ℃ does not exceed 50%, at lower temperatures can have a higher relative humidity, the wettest month of the average maximum relative temperature of 90%. The monthly average maximum relative temperature of the wettest month is 90%, while the average minimum temperature of the month is +25℃, taking into account the condensation that occurs on the surface of the product due to temperature changes.
  3. Altitude:
    The altitude of the installation site should not exceed 2000m, and above 2000m, it should be used with reduced capacity.

Technical Parameters

Technical Parameters
Product Model DLW1-1600 DLW1-2000 DLW1-3200 DLW1-4000 DLW1-6300
IEC 60947-2 GB/T14048.2
Current Shell Frame nm(A) 1600 2000 3200 4000 6300
Rated Current n(A) 200/400/630/800/1000 1250/1600 400/630/800/1000/1250/1600/2000 2000/2500/2900/3200 3200/3600/4000 4000/5000/6300
Number of Poles 3P/3PN/4P 3P/3PN/4P 3P/3PN/4P 3P/3PN/4P 3P/3PN/4P
Operation Frequency (Hz) 50/60
Rated Working Voltage Ue(V) 400/690
Rated Insulation Voltage Ui(V) 1000
Rated Impulse Withstand
Voltage
Uimp(KV) 12
Rated Ultimate Short Circuit AC400V 65 80 100 100 80 120
Breaking Capacity Icu(kA) AC690V 50 65 75 75 65 85
Rated Service Short Circuit
Breaking Capacity Ics (kA)
AC400V 55 80 85 85 80 100
AC690V 42 65 75 75 65 85
Rated Short Time Withstand AC400V 42 65 85 85 60 100
Current Icw(kA) AC690V 35 50 75 75 50 85
Rated Chort Time Withstand
Current Icm(kA)
AC400V 143 176 220 220 176 264
AC690V 105 143 165 165 143 187
Operating Time(ms) Disconnect <30ms
Connect ≤60ms
Flying Arc Distance 0
Operational Performance
(Times)
Mechanical life With Maintenance 30000 30000 20000 25000 15000 10000
Without Maintenance 15000 15000 75000 12500 6500 5000
Operating Frequency 60 times/hour
Electrical life AC400V 10000(200~1000A)
8000(1250~1600A)
15000(400~800A)
14000(1000~1600A)
10000(2000A)
15000(2000~2500A)
12500(2900A)
10000(3200A)
6000 6000 1500
AC690V 10000(200~1000A)
5000(1250~1600A)
15000(400~1250A)
7000(1600A)
5000(2000A)
15000(2000A)
9000(2500A)
5000(2900~3200A)
4500 3000 800
Operating Frequency 20 times/hour
Isolation Function
Protection
Intelligent Controller(M Type)
N-level Protection Function(Only 3PN &4P)
Use and Installation
Operating Temperature -25℃~+70℃ average value within 24h does not exceed +35℃(customization is required for exceeding this temperature range)
Operating Temperature Ambient air temperature of +40℃,atmospheric relative humidity not exceding 50%,maximum relative humidity not exceding 90%at+20℃.
Altitude ≤2000m
Type of use B
Installation Type Main circuit IV
Auxiliary,control circuit
Pollution level 3
Connection method Horizontal/Vertical Horizontal/Vertical/Extension Horizontal/Vertical/Extension Horizontal Horizontal
Installation method Fixed Type Draw-out Type Fixed Type Draw-out Type Fixed Type Draw-out Type Fixed Type Draw-out Type Fixed Type Draw-out Type
Width(W/W1) 260/330 275/345 340/435 375/470 400/515 435/550 537(3P) 550/812 802/886 816/895
Height(H) 310 345 402 425 402 425 402 432 405 432
Depth(D) 240 330 373 445 363 445 413 494 413 494
■Yes □Optional —No

Installation

Installation category

Rated operating voltage of 660V (690V) and below circuit breakers and undervoltage disconnectors, the primary coil of the power transformer is used for installation category IV; auxiliary circuits and control circuits are installed in category III.

Installation conditions

The circuit breaker shall be installed according to the requirements of this manual, and the vertical inclination of the circuit breaker shall not exceed 5 degrees (the inclination of the mining circuit breaker shall not exceed 15 degrees).

  • Fixed circuit breaker installation dimensions and external dimensions (DLW1-2000/3, 2000/4).

Installation Dimensions of DLW Series Intelligent Universal Type Air Circuit Breaker (ACB)

  • Fixed circuit breaker installation dimensions and external dimensions (DLW1-3200/3, 3200/4).

Installation Dimensions of DLW Series Intelligent Universal Type Air Circuit Breaker (ACB)-2

Drawer type circuit breaker installation dimensions and external dimensions
  • Drawer type circuit breaker installation dimensions and external dimensions (DLW1-2000/3, 2000/4)

Installation Dimensions of DLW Series Intelligent Universal Type Air Circuit Breaker (ACB)-3

  • Drawer type circuit breaker installation dimensions and external dimensions (DLW1-3200/3, 3200/4)

Installation Dimensions of DLW Series Intelligent Universal Type Air Circuit Breaker (ACB)-4

  • Installation dimensions and external dimensions of drawer type circuit breaker (DLW1-6300/3, 6300/4 In=4000, 5000A)

Installation Dimensions of DLW Series Intelligent Universal Type Air Circuit Breaker (ACB)-5

  • Installation dimensions and external dimensions of drawer type circuit breaker (DLW1-6300/3, In=6300/4)

Installation Dimensions of DLW Series Intelligent Universal Type Air Circuit Breaker (ACB)-6

  • Mounting dimensions and external dimensions of drawer type circuit breaker (DLW1-6300/3 In=6300A)

Installation Dimensions of DLW Series Intelligent Universal Type Air Circuit Breaker (ACB)-7

Distributed from door frame size and installation

Installation Dimensions of DLW Series Intelligent Universal Type Air Circuit Breaker (ACB)-8

Inm a mm b mm c mm
2000 306 345 0
3200, 4000/3 366 405 0
4000/4 306 345 20
6300 366 405 20