DLM1 Series Moulded Case Circuit Breaker(MCCB)

DLM1 series Moulded Case Circuit Breakers (hereinafter referred to as Circuit Breakers) are suitable for use in power distribution networks with AC 50Hz (or 60Hz), rated insulation voltage of 800V, rated working voltage of 690V and below, and rated current up to 1250A, and are used as electrical equipments for distribution of electric energy and protection of overload, under-voltage and shortcircuit protection of wiring and power supply equipments.

The Circuit Breakers with 630A shell frame rating or below can also be used as overload, under-voltage and short-circuit protection of electric motor. The Circuit Breakers can also be used as overload, undervoltage and short-circuit protection for electric motors.

Under normal conditions, they can also be used for infrequent switching of lines and infrequent starting of motors.

According to its rated ultimate short-circuit breaking capacity, the circuit breaker is divided into three types: L-type (standard type), M-type (higher breaking type) and H-type (high breaking capacity type).

Overview

Product Overview

DLM1 series Moulded Case Circuit Breakers (hereinafter referred to as Circuit Breakers) are suitable for use in power distribution networks with AC 50Hz (or 60Hz), rated insulation voltage of 800V, rated working voltage of 690V and below, and rated current up to 1250A, and are used as electrical equipments for distribution of electric energy and protection of overload, under-voltage and shortcircuit protection of wiring and power supply equipments.

The Circuit Breakers with 630A shell frame rating or below can also be used as overload, under-voltage and short-circuit protection of electric motor. The Circuit Breakers can also be used as overload, undervoltage and short-circuit protection for electric motors.

Under normal conditions, they can also be used for infrequent switching of lines and infrequent starting of motors.

According to its rated ultimate short-circuit breaking capacity, the circuit breaker is divided into three types: L-type (standard type), M-type (higher breaking type) and H-type (high breaking capacity type).

The Circuit Breaker is characterized by small size, high breaking capacity, short flying arc, anti-vibration and so on.

The Circuit Breaker can be installed vertically (i.e. vertically mounted) or horizontally (i.e. horizontally mounted).

The Circuit Breaker conforms to: IEFC60947-2, GB14048.2 standard.

Model

DLM1 Series Moulded Case Circuit Breaker

Note:
  1. According to the rated ultimate short-circuit breaking capacity of
    the product is divided into: L-type (standard), M-type (higher breaking type), H-type (high breaking type).
  2. No code for handle direct operation; Electric operation is indicated by P; Rotating handle is indicated by Z.
  3. No code for circuit breaker for power distribution; Motor protection is indicated by 2.
  4. According to the number of poles of the product is divided into 3 pole and 4 pole. There are four types of neutral pole (N pole) in four-pole products.
    Type A: N-pole is not installed with over-current tripter. and N-pole is always on, not split or closed with other three poles.
    Type B: N-pole is not installed with over-current tripter, N-pole and the other 3 poles split or closed together (N-pole first closed and then split).
    Type C: N pole is installed with over-current tripter, and N pole is split or closed with other 3 poles (N pole is closed first and then split).
    Type D: N-pole is installed with over-current tripter, and N-pole is alwavs on, not split or closed with the other three poles.
The Normal Working Conditions And Installaticn Conditions
  • Altitude: <2000m;
  • Maximum inclination is 22.5°;
  • Ambient temperature: -5℃~ +40℃;
  • In a medium with no danger of explosion, and the mediumis not sufficiently corrosive;
  • Withstand the effects of humid air;
  • Metal and insulation-destroying gases and conductive dust places;
  • Withstand the effects of salt spray and oil mist;
  • Where there is no rain or snow intrusion;
  • Pollution class 3;
  • Installation category ll.

Technical Parameters

Technical Parameters
Model Number DLM1-63 DLM1-125 DLM1-250 DLM1-400 DLM1-630 DLM1-800
Electric characteristics as per IEC 60947-2, EN 60947-2
Rated current (A) In 40℃ 10, 16, 20, 25, 30, 32, 40, 50, 63 25, 30, 32, 40, 50, 63, 80, 100, 125 100, 125, 140, 150, 160, 175, 180, 200, 225, 250 250, 300, 315, 320, 350, 400 400, 450, 500, 630 630,700,800
Rated insulation voltage (V) Ui 800 800 800 800 800 800
Rated impulse withstand voltage (kV) Uimp 8 8 8 8 8 8
Code for breaking capacity L M L M H L M H L M H L M H L M H
Rated ultimate short circuit breaking capacity (kA) 25 50 25 50 85 36 50 85 36 50 85 50 65 100 50 65 100
Rated service short-circuit breaking capacity (kA) 400V/690V 12.5 25 12.5 25 42.5 18 25 42.5 18 25 42.5 25 32.5 50 25 32.5 50
Rated service short-circuit breaking capacity Ics (%lcu) 100% 100% 100% 100% 100% 100%
Cat A
Poles number 3,4 2, 3, 4 2, 3, 4 3,4 3,4 3,4
Maintainable mechanical life (times) 20000 20000 20000 10000 10000 10000
Electrical life(times) 3000 3000 3000 2000 2000 2000
Flying Arc Distance(mm) ≤50 ≤50 ≤50 ≤100 ≤50 ≤50
Accessories

Accessories of DLM1 Series Moulded Case Circuit Breaker

Dimensions

Height of electric operating mechanism

Height of CD&CD2 electric operating mechanism

Model of circuit breaker for operating mechanism DLM1-63L, M DLM1-100L, M, H DLM1-225L, M, H DLM1-400L, M, H DLM1-630L, M, H DLM1-800M, H
Height(mm) CD2 motor type 90.5 89.5 93 142 153 146
CD motor type 141 141 150
External accessories installation method and its overall dimensions

DLM1 Series External accessories installation method and its overall dimensions

DLM1 Series Schematic diagram of CS2-A type handle mounting opening

Note:
It is recommended to purchase the operating mechanism from our company at the same time when ordering. If the user purchases by himself, due to the quality of other companies of the operating mechanism of all the adverse consequences arising from the quality of the company will not be responsible for the company.

Installation of external accessories and their external dimensions
External Accessories Model of External Accessories Matching Circuit Breakers Manual Mounting Dimensions (mm) Mounting Method
H A B A B
Metal Plastic / / / /
Manual Operating Mechanism CD2-100/M DLM1-100 49 69 104 30 / / Vertical Mounting
CD2-225/M DLM1-225 55 72 143 35 / /
CD2-400/M DLM1-400 76 110 194 138 / /
CD2-630/M DLM1-630 83 110 200 168 / /
CD2-100/M DLM1-100 46 / 35 30 / / Vertical Mounting
CD2-100/M DLM1-100 46 / 37 30 / / Horizontal Mounting
CD2-225/M DLM1-225 48 / 35 31 / / Vertical Mounting
CD2-225/M DLM1-225 48 / 45 32 / / Horizontal Mounting
CD2-400/M DLM1-400 61 / 65 15 / / Vertical Mounting
CD2-630/M DLM1-630 61 / 60 15 / /
Solenoid CDM3-100/M DLM1-100 91 / 103.5 30 117.5 90
CDM3-225/M DLM1-225 101 / 143 35 155 105
Electric Motor CD-400/M DLM1-400 141 / 226 132 / /
CD-630/M DLM1-630 140 / 226 132 / /

Note: DLM1L-100~630 and DLM1E-100~630 are both universal DLM1-100~630 external accessories.

Have you
Any Questions?

Can’t find an answer to your question, or want more information about our products? If so, please feel free to get in touch with our professional team. We’re here to help you drive your projects to success.

Contact us for a quotation